Description
Output Power: 30kW@ output voltage ≥300Vdc
Input Voltage: 285-475Vac, three-phase + PE
Output Voltage Range: 100-1000Vdc, default value: 200Vdc
Output Current Range: 0~100A
Voltage stabilised accuracy: ≤±0.5%
Current stabilised accuracy: ≤±1%
Current Sharing Imbalance: ≤±3%
Ripple Peak to Peak: ≤±1%
Storage Temperature: -40℃~+75℃
Relative Humidity: ≤95% RH without condensation
Size(W×D×H): 360×459×85mm
Efficiency(full load): >95.5%
Cooling Mode: Fan cooling
Communication Method: CAN bus
Parallel Module Quantity: ≤60 pieces
Indicator: Green: normal operation Yellow: alarm Red: fault
Certification: CE/Dekra/EMC
Power Factor: ≥0.95(6kw≤output power≤15kw); ≥0.98(15kw≤ output power≤30kw)
ITHD: ≤5%(15kw≤output power≤30kw)
Operating Temperature: -40℃~75℃, output derating above 55℃
Altitude: No derating below 2000m,When the altitude is above 1000m, it needs to set the actual altitude value, the working temperature decreases by 1℃ for each additional 100m
Standby Power consumption: 13W+/-0.5W
Reviews
There are no reviews yet.