Altitude: No derating below 2000m,When the altitude is above 1000m, it needs to set the actual altitude value, the working temperature decreases by 1℃ for each additional 100 m
Input Voltage: 260-530Vac, three-phase + PE
Power Factor: ≥0.95(6kw≤output power≤15kw); ≥0.98(20kw≤output power≤40kw)
ITHD: ≤5%(15kw≤output power≤30kw)
Output Voltage Range: 100-1000Vdc
Output Current Range: 0-100A continuously regulated
Voltage stabilised accuracy: ≤±0.5%(100V-1000V,0~20MHz)
Current stabilised accuracy: ≤±1%(Output current 20% rated current~100% rated current value)
Current Sharing Imbalance: ≤±3%
Ripple Peak to Peak: ≤1%(voltage stabilisation status, input voltage 323Vac~530Vac, output voltage 200Vdc~ 1000Vdc, output current 0~rated current)
Operating Temperature: -40℃~75℃, output derating above 55℃
Storage Temperature: -40℃~+75℃
Relative Humidity: ≤95% RH without condensation
Size(W×D×H): 360×459×85mm
Efficiency(full load): >95.5%
Cooling Mode: Fan cooling
Standby Power consumption: 13W+/-0.5W
Communication Method: CAN bus
Parallel Module Quantity: ≤60 pieces
Indicator: Green: normal operation Yellow: alarm Red: fault
Certification: CE/TUV/EMC cTUVus