Model No.
|
DW30
|
AC Input
|
Input Rating
|
(CE model) 380 ~ 415 Vac ± 15% / (Compatible to UL/cUL model) 480 Vac
|
AC Input Connection
|
3P + N + PE ( Wye configuration), TN/TT (UL,EU) and IT(EU)
|
Max. Input Current (A)
|
60A
|
Frequency (Hz)
|
50 / 60
|
Power Factor
|
>0.99 @ full load
|
Efficiency (%)
|
≧94.5% at nominal output power
|
DC Output
|
Output Voltage Range
|
150~500Vdc (CHAdeMO) / 150~950Vdc (CCS)
|
Max. Output Current
|
60A@500Vdc / 31.5A@950 Vdc
|
Max. Output Power (kW)
|
30 ± 1%
|
Voltage Accuracy (%)
|
± 1
|
Current Accuracy (%)
|
± 1
|
User Interface & Control
|
Display
|
7″ TFT-LCD
|
Push Buttons
|
Operation push button/system power source key switch (or ON/OFF switch, either)
|
User Authentication
|
RFID System ISO / IEC14443A/B
|
Communication
|
External
|
Ethernet / WiFi /3G,4G
|
Internal
|
CANbus / RS485
|
Environmental
|
Operating Temperature (°C)
|
-30 ~ 50, power deration from 50 and above
|
Humidity (%)
|
5~90% RH, non-condensing
|
Altitude (m)
|
≦ 2000m
|
IP Level
|
IP 55 / IK10 (not include screen and RFID module)
|
Cooling method
|
Fan cooling
|
Mechanical
|
Dimension (WxDxH mm)
|
680 x 230 x 690
|
Weight (kg)
|
Single Gun : ≦80kg / Dual Gun : ≦88kg
|
The Cable Length of Charging Connector (m)
|
3
|
Protection
|
Input Protection
|
OVP, OCP, OPP, OTP, UVP, Residual current detection, transient voltage
|
Output Protection
|
Output shor, OCP, OVP, UVP, OTP, Leakage current
|
Regulation
|
Certificate
|
IEC 61851-1, IEC 61851-23, IEC 61851-21-2, UL2597, UL2202
|
Safety
|
CE, UL/cUL, GB/T and ChAdeMO v1.2
|
Charging Interface
|
CHAdeMO 1.2, ISO15118, DIN 70121, GB/T 27930-2015
|